/* Void Main's man pages */

{ phpMan } else { main(); }

Command: man perldoc info search(apropos)  


AIPTEK(4)                                                                                                              AIPTEK(4)



NAME
       aiptek - Aiptek USB Digital Tablet Input Driver for Linux

SYNOPSIS
       Section "InputDevice"
         Identifier "idevname"
         Driver "aiptek"
         Option "Device"   "devpath"
         ...
       EndSection

DESCRIPTION
       aiptek is an Xorg input driver for Aiptek HyperPen USB-based tablet devices.  This driver only supports the USB protocol,
       and only under Linux; for RS-232C-based HyperPens, please see the "hyperpen" driver.

       The aiptek driver functions as a pointer input device, and may be used as the X server's core pointer.

SUPPORTED HARDWARE
       This driver supports the Aiptek HyperPen 4000U, 5000U, 6000U, 8000U and 12000U USB-based input tablet on some Linux plat-
       forms.

CONFIGURATION DETAILS
       Please  refer  to xorg.conf(5) for general configuration details and for options that can be used with all input drivers.
       This section only covers configuration details specific to this driver.

       Multiple instances of the Aiptek devices can cohabit. It can be useful to define multiple devices with  different  active
       zones. Each device supports the following entries:

               Option "Type" "stylus"|"eraser"|"cursor"
                   sets the type of tool the device represent. This option is mandatory.

               Option "Device" "path"
                   sets  the  path  to  the  special file which represents serial line where the tablet is plugged.  You have to
                   specify it for each subsection with the same value if you want to have multiple devices with the same tablet.
                   This option is mandatory.

               Option "USB" "on"
                   specifies  that you are using the USB bus to communicate with your tablet.  This setting is mandatory, as USB
                   is the only protocol supported by this driver.

               Option "DeviceName" "name"
                   sets the name of the X device.

               Option "Mode" "Relative"|"Absolute"
                   sets the mode of the device.

               Option "HistorySize" "number"
                   sets the motion history size. By default the value is zero.

               Option "AlwaysCore" "on"
                   enables the sharing of the core pointer. When this feature is enabled, the device will take  control  of  the
                   core  pointer  (and  thus  will emit core events) and at the same time will be able, when asked so, to report
                   extended events.  You can use the last available integer feedback to control this feature. When the value  of
                   the feedback is zero, the feature is disabled. The feature is enabled for any other value.

               Option "XTop" "number"
                   First of three sets of parameters to set the active zone. This sets the X coordinate of the top corner of the
                   active zone. "TopX" is a synonym.

               Option "YTop" "number"
                   First of three sets of parameters to set the active zone. This sets the Y coordinate of the top corner of the
                   active zone. "TopY" is a synonym.

               Option "XBottom" "Inumber"
                   First  of three sets of parameters to set the active zone. This sets the X coordinate of the bottom corner of
                   the active zone. "BottomX" is a synonym.

               Option "YBottom" "number"
                   First of three sets of parameters to set the active zone. This sets the Y coordinate of the bottom corner  of
                   the active zone. "BottomY" is a synonym.

               Option "XMax" "number"
                   Second  of three sets of parameters to set the active zone. This sets the the X coordinate of the bottom cor-
                   ner of the active zone. The Top X corner's coordinate is fixed at 0. "MaxX" is a synonym.

               Option "YMax" "number"
                   Second of three sets of parameters to set the active zone. This sets the the Y coordinate of the bottom  cor-
                   ner of the active zone. The Top Y corner's coordinate is fixed at 0. "MaxY" is a synonym.

               Option "XOffset" "number"
                   Third of three sets of parameters to set the active zone. This sets the X coordinate of the top corner of the
                   active zone. "OffsetX" is a synonym.

               Option "YOffset" "number"
                   Third of three sets of parameters to set the active zone. This sets the Y coordinate of the top corner of the
                   active zone. "OffsetY" is a synonym.

               Option "XSize" "number"
                   Third  of three sets of parameters to set the active zone. This sets the X coordinate of the bottom corner of
                   the active zone. Unlike others, this parameter is expressed in relative coordinates from the "XOffset" param-
                   eter. "XSize" is a synonym.

               Option "YSize" "number"
                   Third  of three sets of parameters to set the active zone. This sets the Y coordinate of the bottom corner of
                   the active zone. Unlike others, this parameter is expressed in relative coordinates from the "YOffset" param-
                   eter. "YSize" is a synonym.

               Option "ZMin" "number"
                   Minimum pressure reading that will be accepted from the Stylus tool. "MinZ" is a synonym.

               Option "ZMax" "number"
                   Maximum pressure reading that will be accepted from the Stylus tool. "MaxZ" is a synonym.

               Option "XThreshold" "number"
                   Minimal change in X coordinate position that will be accepted as data input.  "ThresholdX" is a synonym.

               Option "YThreshold" "number"
                   Minimal change in Y coordinate position that will be accepted as data input.  "ThresholdY" is a synonym.

               Option "ZThreshold" "number"
                   Minimal change in pressure reading that will be accepted as data input.  "ThresholdZ" is a synonym.

               Option "InvX" "on"
                   Inverts X coordinate reports. "XInv" is a synonym.

               Option "InvY" "on"
                   Inverts Y coordinate reports. "YInv" is a synonym.

               Option "Pressure" "soft"|"hard"|"linear"
                   Pressure  reports  either delivered in linearly incremental values (default), or perturbed by one of two log-
                   linear algorithms ("soft" or "hard".)

               Option "KeepShape" "on"
                   When this option is enabled, the active zone  begins according to  TopX  and  TopY.   The  bottom  corner  is
                   adjusted  to  keep the ratio width/height of the active zone the same as the screen while maximizing the area
                   described by the active area  set  of  parameters,  XTop/YTop/XBottom/YBottom,  XMax/YMax,  or  XOffset/YOff-
                   set/XSize/YSize.

               Option "DebugLevel" number
                   sets the level of debugging info reported.

       This driver is currently Linux specific.

SEE ALSO
       Xorg(1), xorg.conf(5), Xserver(1), X(7), hyperpen(4).

AUTHORS
       Bryan W. Headley <bheadleyATearthlink.net>

PROJECT PAGE
       http://aiptektablet.sourceforge.net  tracks ongoing development of this driver, the Linux kernel driver, and a GUI front-
       end application that works in concert with the above.



X Version 11                                         xf86-input-aiptek 1.3.1                                           AIPTEK(4)

Valid XHTML 1.0!Valid CSS!